5
Group Name Cmd
Resp
Description
Write
value
value
value
Values Index #1 Index #2
SYSTEM
DIESE # #
Request the retrieval of all the
variables
Rd/Wr
0 1 0
READY * * Ready Device Flag Rd 0 1 0
0= Initialization in progress
1 = Ready
DEV ? DEV MMS device type Rd 74 74 74 74 = OPS-300
CONTROLS
UPDATER yU yU Device reboot for update Rd/Wr
0 255 0 1 then 254 => Reboot
FACTORYRESET YR YR
Apply factory settings to the
device( except image settings )
Rd/Wr
0 1 0
POSMEMORYRESET YE YE Erase stored image settings Rd/Wr
0 1 0
CSTORE YS YS
FLASH memory writing in
progess. Do not power off
Rd 0 1 0
0 = Free
1 = Flash writing in progress
LOCK YK YK Device locking Rd/Wr
0 2 0
0 = No lock
1 = Locked menu
2 = Locked front panel
LCDBRIGHTNESS YB YB Front panel display brightness Rd/Wr
1 8 8
1, …, 8 = Brightness level, 12,5%
step
KEYBRIGHTNESS Yb Yb Front panel keys brightness Rd/Wr
10 100 100
1, …, 100 = Brightness level, 1%
step
TBAR_ENABLE YD YD Enable disable T-BAR Rd/Wr
0 1 1
COPKIND CK CK Kind of slow in-
Rd 0 6 0
0 = None
1 = Auto centering
2 = Auto setting
3 = StandBy
4 = Picture recording
5 = Reset to default factory setting
6 = Reset User settings
COPPROGRESS CP CP
Progress percent of the slow
operation
Rd 0 100 0 Percent : 0 to 100%
PRESET_MATRIX_MGMT CR CR
Preset management in matrix
mode from the front panel
Rd/Wr
0 3 0
0 = Preset management for both
outputs
1 = Preset management for current
output
2 = Preset management for output 1
3 = Preset management for output 2
SWITCHER_MODE CM CM Device operating mode Rd/Wr
0 1 0
0 = Seamless switcher mode
1 = Matrix mode
yA yA Device is driven by Orchestra Rd/Wr
0 1 0
0 = Device is not driven by ORC-50
1 = Device is driven by Orc-50
YL YL
Forbide the use of a signal-less
input
Rd/Wr
0 1 1
0 = Signal less input can be selected
1 = Signal less input can not be
selected
YT YT
Automatic Take after an input
change
Rd/Wr
0 1 0
0 = AUTO-TAKE Disable
1 = AUTO-TAKE Enable