46
Group Name Cmd
Resp
Description
Read /
Write
Min
value
Max
value
Default
value
Values Index #1 Index #2
ORATE OR OR Output rate Rd/Wr
0 12 8
0 = Custom Field Rate
1 = 23,97 Hz
2 = 24 Hz
3 = 25 Hz
4 = 29,97 Hz
5 = 30 Hz
6 = 50 Hz
7 = 59,94 Hz
8 = 60 Hz
9 = 72 Hz
10 = 75 Hz
11 = 85 Hz
12 = 100 Hz
0 = Main output
1 = Preview
output
2 = Recording
output
OSIGTYPEANALOG OA OA
Analog output type
Rd/Wr
0 3 0
0 = RGBs
1 = RGsB (SOG)
2 = RGB H&V
3 = YUV
0 = Main output
1 = Preview
output
2 = Recording
output
OSIGTYPEDIGITAL OD OD Digital output type Rd/Wr
0 2 0
0 = RGB 0-255 ( full scale )
1 = RGB 16-235 ( reduced scale )
2 = YUV
0 = Main output
1 = Preview
output
2 = Recording
output
OSYNCPOL OS OS
Analog output sync polarity
Rd/Wr
0 3 0
0 = negative H&V synchro
1 = Synchros H négative et V
positive
2 = Synchros H positive et V
négative
3 = Synchros H et V positives
0 = Main output
1 = Preview
output
2 = Recording
output