Analog-way OPS300 Programmer's Guide Manuale Utente Pagina 20

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 58
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 19
20
Group Name Cmd
Resp
Description
Read /
Write
Min
value
Max
value
Default
value
Values Index #1 Index #2
SIG_HTOTAL_MAXI sM sM
Maximal number of pixels per
input line
Rd 0 65535
0 Unit = pixels
0 = Input1
1 = Input2
2 = Input3
3 = Input4
4 = Input5
5 = Input6
6 = Input7
7 = Input8
8 = Input9
9 = Input10
10 = Input11
11 = Input12
SIG_WIDTH sw sw Input displayed pixel count Rd 0 65535
0 Unit = pixels
0 = Input1
1 = Input2
2 = Input3
3 = Input4
4 = Input5
5 = Input6
6 = Input7
7 = Input8
8 = Input9
9 = Input10
10 = Input11
11 = Input12
SIG_HEIGHT st st Input displayed line count Rd 0 65535
0 Unit = pixels
0 = Input1
1 = Input2
2 = Input3
3 = Input4
4 = Input5
5 = Input6
6 = Input7
7 = Input8
8 = Input9
9 = Input10
10 = Input11
11 = Input12
Vedere la pagina 19