Group Name Cmd
Resp
Description
Read /
Write
Min
value
Max
value
Default
value
Values Index #1 Index #2
OISHDCP On On Output HDCP status Rd 0 1 0
0 = Main output
1 = Preview
output
2 = Recording
output
OSYNCOUTPUT Om Om
Output 2 copies the format and
rate of output 1
Rd/Wr
0 1 0
REFERENCE
REFREQUEST
Xr
Xr
Framelock source requested by
user
Rd/Wr
0 16 0
0 = Analog input 1 as reference
1 = Analog input 2 as reference
2 = Analog input 3 as reference
3 = Analog input 4 as reference
4 = Analog input 5 as reference
5 = Analog input 6 as reference
6 = Analog input 7 as reference
7 = Analog input 8 as reference
8 = DVI 1 input as reference
9 = DVI 2 input as reference
10 = SDI 1 input as reference
11 = SDI 2 input as reference
14 = Back End 1 as reference
15 = Back End 2 as reference
16 = Back End 3 as reference
0 = Main output
1 = Preview
output
2 = Recording
output
REFCURRENTREQUEST
Xe
Xe
Current Frame Lock source Rd/Wr
0 16 0
0 = Analog input 1 as reference
1 = Analog input 2 as reference
2 = Analog input 3 as reference
3 = Analog input 4 as reference
4 = Analog input 5 as reference
5 = Analog input 6 as reference
6 = Analog input 7 as reference
7 = Analog input 8 as reference
8 = DVI 1 input as reference
9 = DVI 2 input as reference
10 = SDI 1 input as reference
11 = SDI 2 input as reference
14 = Back End 1 as reference
15 = Back End 2 as reference
16 = Back End 3 as reference
0 = Main output
1 = Preview
output
2 = Recording
output
REFMODE
Xm
Xm
Follow mode requested by user Rd/Wr
0 5 0
0 = Internal
1 = Follow x1/2
2 = Follow x1
3 = Follow x2
4 = Follow x3
5 = Asynchronous Follow
0 = Main output
1 = Preview
output
2 = Recording
output