14
Group Name Cmd
Resp
Description
Write
value
value
value
Values Index #1 Index #2
IN_KEYING_INVERT KI KI Invert keying area Rd/Wr
0 1 0
0 = Input1
1 = Input2
2 = Input3
3 = Input4
4 = Input5
5 = Input6
6 = Input7
7 = Input8
8 = Input9
9 = Input10
10 = Input11
11 = Input12
IN_KEYING_GRAB_ENABLE Kg Kg
Enable/disable the keying color
grabber mode
Rd/Wr
0 1 0
0 = Disable the grabber
1 = Enable the grabber
IN_KEYING_GRAB_GET Kc Kc
Capture the coolor selected by
the grabber and apply the
settings
Rd/Wr
0 1 0 Percent of OSCREEN_UTIL_H
IN_KEYING_GRAB_H Kh Kh Horizontal position of the grabber
Rd/Wr
0 65535
32768 Precent of OSCREEN_UTIL_V
IN_KEYING_GRAB_V Kv Kv Vertical position of the grabber Rd/Wr
0 65535
32768
INPUT
STATUS
SIG_HPOL sh sh Input H sync polarity Rd 0 1 0
0 = Negative Synchro
1 = Positive Synchro
0 = Input1
1 = Input2
2 = Input3
3 = Input4
4 = Input5
5 = Input6
6 = Input7
7 = Input8
8 = Input9
9 = Input10
10 = Input11
11 = Input12
SIG_VPOL sv sv Input V sync polarity Rd 0 1 0
0 = Negative Synchro
1 = Positive Synchro
0 = Input1
1 = Input2
2 = Input3
3 = Input4
4 = Input5
5 = Input6
6 = Input7
7 = Input8
8 = Input9
9 = Input10
10 = Input11
11 = Input12