Group Name Cmd
Resp
Description
Read /
Write
Min
value
Max
value
Default
value
Values Index #1 Index #2
SET_QUAD_LAYOUT NQ NQ
Quadravision Layout request
(auto-reset)
Rd/Wr
13 25 0
13 = Reset of layer properties
14 = Background Live + Top Left
PiP
15 = Background Live + Top Right
PiP
16 = Background Live + Bottom Left
PiP
17 = Background Live + Bottom
Right PiP
18 = Background Frame + 2 Left
Right PiPs
19 = Background Frame + 2 Top
Bottom PiPs
20 = Background Frame + 1 Right
PiP + 2 Top Bottom PiPs
21 = Background Frame + 1 Left PiP
+ 2 Top Bottom PiPs
22 = Background Frame + 1Top PiP
+ 2 Left Right PiPs
23 = Background Frame + 1 Bottom
PiP + 2 Left Right PiPs
24 = Background Frame + 3
horizontal PiPs
25 = Background Frame + 3
diagonal PiPs
SETTINGS
R_FLICK Rf Rf
Anti
-flicker level Rd/Wr
0 7 2 0 = No antif-flicker
0 = Main output
1 = Preview
output
2 = Recording
output
R_GAMMA Rg Rg Gamma correction level Rd/Wr
5 40 10 Unit = 1/10
0 = Main output
1 = Preview
output
2 = Recording
output
R_SHARPNESS Rs Rs Sharpness correction Level Rd/Wr
0 255 128 128 = neutral
0 = Main output
1 = Preview
output
2 = Recording
output