Analog-way OPS300 Programmer's Guide Manuale Utente Pagina 15

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 58
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 14
15
Group Name Cmd
Resp
Description
Read /
Write
Min
value
Max
value
Default
value
Values Index #1 Index #2
SIG_SYNC_TYPE sK sK Input sync type Rd 0 3 0
0 = Séparated Synchros H&V
1 = Composite TTL Synchro
2 = Composite Analog Synchro
3 = Synchro on Green (SOG)
0 = Input1
1 = Input2
2 = Input3
3 = Input4
4 = Input5
5 = Input6
6 = Input7
7 = Input8
8 = Input9
9 = Input10
10 = Input11
11 = Input12
SIG_FREQ_FIELD sf sf Input frame frequency Rd 0 65535
0 Unit = 1/100Hz
0 = Input1
1 = Input2
2 = Input3
3 = Input4
4 = Input5
5 = Input6
6 = Input7
7 = Input8
8 = Input9
9 = Input10
10 = Input11
11 = Input12
SIG_FREQ_LINE sl sl Input line frequency Rd 0 65535
0 Unit = 1/100Hz
0 = Input1
1 = Input2
2 = Input3
3 = Input4
4 = Input5
5 = Input6
6 = Input7
7 = Input8
8 = Input9
9 = Input10
10 = Input11
11 = Input12
Vedere la pagina 14
1 2 ... 10 11 12 13 14 15 16 17 18 19 20 ... 57 58

Commenti su questo manuale

Nessun commento