Group Name Cmd
Resp
Description
Read /
Write
Min
value
Max
value
Default
value
Values Index #1 Index #2
SET_FREEZE Sf Sf Freeze of the input Rd/Wr
0 1 0 1 = Freeze
0 = Input1
1 = Input2
2 = Input3
3 = Input4
4 = Input5
5 = Input6
6 = Input7
7 = Input8
8 = Input9
9 = Input10
10 = Input11
11 = Input12
SET_MOTION_DETECT Sm Sm
0 : max correction; 15 : min
correction
Rd/Wr
0 15 15
0 = Input1
1 = Input2
2 = Input3
3 = Input4
4 = Input5
5 = Input6
6 = Input7
7 = Input8
8 = Input9
9 = Input10
10 = Input11
11 = Input12
PRESET
ELEMENT
PE_INPUTNUM IN IN
Displayed input number or frame
or logo number
Rd/Wr
0 12 0
0 = No input
1 = Input1
2 = Input2
3 = Input3
4 = Input4
5 = Input5
6 = Input6
7 = Input7
8 = Input8
9 = Input9
10 = Input10
11 = Input11
12 = Input12
0 = Current
preset
1 = Next preset
2 = Previous
preset
3 = Memory
Preset 1
4 = Memory
Preset 2
5 = Memory
Preset 3
6 = Memory
Preset 4
0 = Background
Frame for output
1
1 = Background
Frame for output
2 in matrix mode
2 = Background
Layer for output 1
3 = Pip 1 Layer
for output1
Background
Layer for output 2
in matrix mode
4 = Pip 2 Layer
for output1
6 = Logo 1
7 = Logo 2
8 = Audio Output
1
9 = Audio Output
2