Group
Name CmdResp
Description
Read
/
Write
Min
Value
Max
value
Default
value
Values Index #1 Index #2
PE_CLOSING_TRANSITION cT cT Layer closing transition type
Rd/Wr
0 2 2
0 = Cut
1 = CleanCut
2 = Fade
0 = Current
preset
1 = Next preset
2 = Previous
preset
3 = Memory
Preset 1
4 = Memory
Preset 2
5 = Memory
Preset 3
6 = Memory
Preset 4
2 =
Background
Layer for
output 1
3 = Pip 1 Layer
for output1
Background
Layer for
output 2 in
matrix mode
8 = Audio
Output 1
9 = Audio
Output 2
PE_CLOSING_TRANSITION_WAY
cW cW
Layer closing transition
direction
Rd/Wr
0 10 0
0 = Current
preset
1 = Next preset
2 = Previous
preset
3 = Memory
Preset 1
4 = Memory
Preset 2
5 = Memory
Preset 3
6 = Memory
Preset 4
2 =
Background
Layer for
output 1
3 = Pip 1 Layer
for output1
Background
Layer for
output 2 in
matrix mode
8 = Audio
Output 1
9 = Audio
Output 2