21
Group
Name CmdResp
Description
Read
/
Write
Min
Value
Max
value
Default
value
Values Index #1 Index #2
SIG_MEM_SLOT sS sS Memory slot index Rd 0 255 255
0 = Input1
1 = Input2
2 = Input3
3 = Input4
4 = Input5
5 = Input6
8 = Input9
9 = Input10
10 = Input11
11 = Input12
INPUT
SETTINGS
SET_HPOS SH SH Input horizontal position
Rd/Wr
0 2048 1024 1024 = neutral
0 = Input1
1 = Input2
2 = Input3
3 = Input4
4 = Input5
5 = Input6
8 = Input9
9 = Input10
10 = Input11
11 = Input12
SET_VPOS SV SV Input vertical position
Rd/Wr
0 2048 1024 1024 = neutral
0 = Input1
1 = Input2
2 = Input3
3 = Input4
4 = Input5
5 = Input6
8 = Input9
9 = Input10
10 = Input11
11 = Input12
SET_HSIZE Sw Sw Input horizontal size
Rd/Wr
0 4096 2048 2048 = neutral
0 = Input1
1 = Input2
2 = Input3
3 = Input4
4 = Input5
5 = Input6
8 = Input9
9 = Input10
10 = Input11
11 = Input12