31
Group
Name CmdResp
Description
Read
/
Write
Min
Value
Max
value
Default
value
Values Index #1 Index #2
PE_POS_V pV pV
Layer top V position on output
screen
Rd/Wr
0 6553532768
Unit = pixels ( 32768 = screen
top border )
0 = Current
preset
1 = Next preset
2 = Previous
preset
3 = Memory
Preset 1
4 = Memory
Preset 2
5 = Memory
Preset 3
6 = Memory
Preset 4
2 =
Background
Layer for
output 1
3 = Pip 1 Layer
for output1
Background
Layer for
output 2 in
matrix mode
8 = Audio
Output 1
9 = Audio
Output 2
PE_SIZE_H pW pW
Layer H size on output screen
(without borders)
Rd/Wr
0 655351600
Unit = pixels ( Max=16x2048 =
32768)
0 = Current
preset
1 = Next preset
2 = Previous
preset
3 = Memory
Preset 1
4 = Memory
Preset 2
5 = Memory
Preset 3
6 = Memory
Preset 4
2 =
Background
Layer for
output 1
3 = Pip 1 Layer
for output1
Background
Layer for
output 2 in
matrix mode
8 = Audio
Output 1
9 = Audio
Output 2