Group Name CmdResp
Description
Read /
Write
Min
Value
Max
value
Default
value
Values Index #1 Index #2
OPATTERN OP OP Output test pattern Rd/Wr 0 8 0
0 = No pattern
1 = Vertical Grey Scale
2 = Horizontal Grey Scale
3 = Vertical Color Bar
4 = Horizontal Color Bar
5 = Grid
6 = SMPTE
7 = Burst
8 = Centering
0 = Main output
1 = Preview output
OBLACK OB OB Output black control Rd/Wr 0 1 0
0 = Normal output
1 = Black output
0 = Main output
1 = Preview output
OUTIL_H OH OH Output H size Rd 0 65535
1600 Unit = pixels
0 = Main output
1 = Preview output
OUTIL_V OV OV Output V size Rd 0 65535
1200 Unit = pixels
0 = Main output
1 = Preview output
OFIELDRATE OT OT Output frame frequency Rd 100 10000
6000 Unit = 1/100Hz
0 = Main output
1 = Preview output
OIMAGE_OVERSCAN OO OO Image Overscan / Underscan Rd/Wr 0 1 0
0 = Main output
1 = Preview output
OSETDETECTHDCP Oh Oh
Enable/disable the Output HDCP
detection
Rd/Wr 0 4 1
0 = Disable HDCP detection
1 = Automatic HDCP detection
2 = HDCP Configuration 1
3 = HDCP Configuration 2
4 = HDCP Configuration 3
0 = Main output
1 = Preview output
OISHDCP On On Output HDCP status Rd 0 1 0
0 = Main output
1 = Preview output
OSYNCOUTPUT Om Om
Output 2 copies the format and
rate of output 1
Rd/Wr 0 1 0
REFERENCE
REFREQUEST
Xr
Xr
Framelock source requested by
user
Rd/Wr 0 15 0
0 = Analog input 1 as reference
1 = Analog input 2 as reference
2 = Analog input 3 as reference
3 = Analog input 4 as reference
8 = DVI 1 input as reference
14 = Back End 1 as reference
15 = Back End 2 as reference
0 = Main output
1 = Preview output
REFCURRENTREQUEST
Xe
Xe
Current Frame Lock source Rd/Wr 0 15 0
0 = Analog input 1 as reference
1 = Analog input 2 as reference
2 = Analog input 3 as reference
3 = Analog input 4 as reference
8 = DVI 1 input as reference
14 = Back End 1 as reference
15 = Back End 2 as reference