Group Name CmdResp
Description
Write
Value
value
value
Values Index #1 Index #2
IN_KEYING_INVERT KI KI Invert keying area Rd/Wr 0 1 0
0 = Input1
1 = Input2
2 = Input3
3 = Input4
8 = Input9
10 = Input11
11 = Input12
IN_KEYING_GRAB_ENABLE Kg Kg
Enable/disable the keying color
grabber mode
Rd/Wr 0 1 0
0 = Disable the grabber
1 = Enable the grabber
IN_KEYING_GRAB_GET Kc Kc
Capture the coolor selected by the
grabber and apply the settings
Rd/Wr 0 1 0 Percent of OSCREEN_UTIL_H
IN_KEYING_GRAB_H Kh Kh Horizontal position of the grabber Rd/Wr 0 65535
32768 Precent of OSCREEN_UTIL_V
IN_KEYING_GRAB_V Kv Kv Vertical position of the grabber Rd/Wr 0 65535
32768
INPUT
STATUS
SIG_HPOL sh sh Input H sync polarity Rd 0 1 0
0 = Negative Synchro
1 = Positive Synchro
0 = Input1
1 = Input2
2 = Input3
3 = Input4
8 = Input9
10 = Input11
11 = Input12
SIG_VPOL sv sv Input V sync polarity Rd 0 1 0
0 = Negative Synchro
1 = Positive Synchro
0 = Input1
1 = Input2
2 = Input3
3 = Input4
8 = Input9
10 = Input11
11 = Input12
SIG_SYNC_TYPE sK sK Input sync type Rd 0 3 0
0 = Séparated Synchros H&V
1 = Composite TTL Synchro
2 = Composite Analog Synchro
3 = Synchro on Green (SOG)
0 = Input1
1 = Input2
2 = Input3
3 = Input4
8 = Input9
10 = Input11
11 = Input12
SIG_FREQ_FIELD sf sf Input frame frequency Rd 0 65535
0 Unit = 1/100Hz
0 = Input1
1 = Input2
2 = Input3
3 = Input4
8 = Input9
10 = Input11
11 = Input12