Analog-way Smart Edge FX - STE200 Programmer's Guide Manuale Utente Pagina 25

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 57
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 24
25
Group Name Cmd
RespDescription
Read /
Write
Min
Value
Max
value
Default
value
Values Index #1 Index #2
Index #3
SET_AUTOCAD Sa Sa Input autocentering reques Rd/Wr
0 1 0
Auto reset
0 = Input1
1 = Input2
2 = Input3
3 = Input4
4 = Input5
5 = Input6
8 = Input9
9 = Input10
10 = Input11
11 = Input12
12 = Input13
13 = Input14
SET_USER_GAIN_R sr sr
ADC R channel adjustment
(advanced setting)
Rd/Wr
0 255 128 128 = neutral
0 = Input1
1 = Input2
2 = Input3
3 = Input4
4 = Input5
5 = Input6
8 = Input9
9 = Input10
10 = Input11
11 = Input12
12 = Input13
13 = Input14
SET_USER_GAIN_G sg sg
ADC G channel adjustment
(advanced setting)
Rd/Wr
0 255 128 128 = neutral
0 = Input1
1 = Input2
2 = Input3
3 = Input4
4 = Input5
5 = Input6
8 = Input9
9 = Input10
10 = Input11
11 = Input12
12 = Input13
13 = Input14
Vedere la pagina 24
1 2 ... 20 21 22 23 24 25 26 27 28 29 30 ... 56 57

Commenti su questo manuale

Nessun commento