24
Group Name Cmd
RespDescription
Read /
Write
Min
Value
Max
value
Default
value
Values Index #1 Index #2
Index #3
SET_HUE Su Su Input hue (NTSC only) Rd/Wr
0 255 128 128 = neutral
0 = Input1
1 = Input2
2 = Input3
3 = Input4
4 = Input5
5 = Input6
8 = Input9
9 = Input10
10 = Input11
11 = Input12
12 = Input13
13 = Input14
SET_HTOTAL ST ST Input total pixel per line Rd/Wr
0 65535
0 Unit = pixels.
0 = Input1
1 = Input2
2 = Input3
3 = Input4
4 = Input5
5 = Input6
8 = Input9
9 = Input10
10 = Input11
11 = Input12
12 = Input13
13 = Input14
SET_PHASE SS
SS Input Phase Rd/Wr
0 31 16
0 = Input1
1 = Input2
2 = Input3
3 = Input4
4 = Input5
5 = Input6
8 = Input9
9 = Input10
10 = Input11
11 = Input12
12 = Input13
13 = Input14