Group Name Cmd
Resp
Description
Read /
Write
Min
Value
Max
value
Default
value
Values Index #1 Index #2
PE_BORDER_SIZE_V bV bV Border V size Rd/Wr 0 127 10 Unit = pixels
0 = Current preset
1 = Next preset
2 = Previous
preset
3 = Memory
Preset 1
4 = Memory
Preset 2
5 = Memory
Preset 3
6 = Memory
Preset 4
2 = Background
Layer for output 1
8 = Audio Output 1
9 = Audio Output 2
PE_OPENING_TRANSITION oT oT Layer opening transition type Rd/Wr 0 2 2
0 = Cut
2 = Fade
0 = Current preset
1 = Next preset
2 = Previous
preset
3 = Memory
Preset 1
4 = Memory
Preset 2
5 = Memory
Preset 3
6 = Memory
Preset 4
2 = Background
Layer for output 1
8 = Audio Output 1
9 = Audio Output 2
PE_OPENING_TRANSITION_WAY oW oW Layer opening transition direction Rd/Wr 0 10 0
0 = Current preset
1 = Next preset
2 = Previous
preset
3 = Memory
Preset 1
4 = Memory
Preset 2
5 = Memory
Preset 3
6 = Memory
Preset 4
2 = Background
Layer for output 1
8 = Audio Output 1
9 = Audio Output 2