5
Group Name CmdResp
Description
Write
Value
value
value
Values Index #1 Index #2
SYSTEM
DIESE # #
Request the retrieval of all the
variables
Rd/Wr
0 1 0
READY * * Ready Device Flag Rd 0 1 0
0= Initialization in progress
1 = Ready
DEV ? DEV
MMS device type Rd 93 93 93 93 = SQD-200
CONTROLS
UPDATER yU yU Device reboot for update Rd/Wr
0 255 0 1 then 254 => Reboot
FACTORYRESET YR YR
Apply factory settings to the
device( except image settings )
Rd/Wr
0 1 0
POSMEMORYRESET YE YE Erase stored image settings Rd/Wr
0 1 0
CSTORE YS YS
FLASH memory writing in progess.
Do not power off
Rd 0 1 0
0 = Free
1 = Flash writing in progress
LOCK YK YK Device locking Rd/Wr
0 2 0
0 = No lock
1 = Locked menu
2 = Locked front panel
LCDBRIGHTNESS YB YB Front panel display brightness Rd/Wr
1 8 8
1, …, 8 = Brightness level, 12,5%
step
KEYBRIGHTNESS Yb Yb Front panel keys brightness Rd/Wr
10 100 100
1, …, 100 = Brightness level, 1%
step
TBAR_ENABLE YD YD Enable disable T-BAR Rd/Wr
0 1 1
COPKIND CK CK Kind of slow in-progress operation
Rd 0 6 0
0 = None
1 = Auto centering
2 = Auto setting
3 = StandBy
4 = Picture recording
5 = Reset to default factory setting
6 = Reset User settings
COPPROGRESS CP CP
Progress percent of the slow
operation
Rd 0 100 0 Percent : 0 to 100%
yA yA Device is driven by Orchestra Rd/Wr
0 1 0
0 = Device is not driven by ORC-50
1 = Device is driven by Orc-50
YL YL
Forbide the use of a signal-less
input
Rd/Wr
0 1 1
0 = Signal less input can be
selected
1 = Signal less input can not be
selected
YT YT
Automatic Take after an input
change
Rd/Wr
0 1 0
0 = AUTO-TAKE Disable
1 = AUTO-TAKE Enable
Ys Ys
Automatic preset toggle after a
TAKE
Rd/Wr
0 1 0
0 = AUTO- PRESET-TOGGLE
Disable
1 = AUTO- PRESET-TOGGLE
Enable
FREEZE_MODE Ym Ym Input freeze mode Rd/Wr
0 1 0
0 = Freeze by input
1 = Freeze all inputs
Commenti su questo manuale