Analog-way OPS200 Programmer's Guide Manuale Utente Pagina 24

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 53
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 23
24
Group Name CmdResp
Description
Read
/
Write
Min
Value
Max
value
Default
value
Values Index #1 Index #2
SET_CROP_WIN_POS_H SI SI
Cropping window horizontal
position
Rd/Wr
0 65535
32768
Percent = 65535 = 100% : all
cropping on the left
0 = Input1
1 = Input2
2 = Input3
3 = Input4
4 = Input5
5 = Input6
6 = Input7
8 = Input9
9 = Input10
10 = Input11
11 = Input12
SET_CROP_WIN_POS_V SJ SJ Cropping window vertical position
Rd/Wr
0 65535
32768
Percent = 65535 = 100% : all
cropping on the top
0 = Input1
1 = Input2
2 = Input3
3 = Input4
4 = Input5
5 = Input6
6 = Input7
8 = Input9
9 = Input10
10 = Input11
11 = Input12
SET_CROP_WIN_SIZE_H SK SK Horizontal cropping
Rd/Wr
0 58981
0 Percent = 65535 = 100%
0 = Input1
1 = Input2
2 = Input3
3 = Input4
4 = Input5
5 = Input6
6 = Input7
8 = Input9
9 = Input10
10 = Input11
11 = Input12
SET_CROP_WIN_SIZE_V SL SL Vertical cropping
Rd/Wr
0 58981
0 Percent = 65535 = 100%
0 = Input1
1 = Input2
2 = Input3
3 = Input4
4 = Input5
5 = Input6
6 = Input7
8 = Input9
9 = Input10
10 = Input11
11 = Input12
Vedere la pagina 23
1 2 ... 19 20 21 22 23 24 25 26 27 28 29 ... 52 53